loading

More than twenty years experience in screw air compressor manufacturing.  

The vortex type air compressor maintenance skills

GeLinKeEr summarizes the vortex type air compressors to maintain key point at ordinary times, as follows:

maintenance

1) Specification: A 2500 hours running below; Specification: B hours per year - in 2500 5000; Specification: C hours running higher than 5000.

2) Check every day. Empty filter first run of 500 hours after the inspection and cleaning time, according to A later every year; B every six months; C change every 3 months. In specific combining site environment, even failure.

3) According to A, be cleaned once every two years. B each operation cleaned once a year; C per run clean once half a year.

4) According to A three years cleaning operation, six years to replace; B cleaning operation for two years, three years to replace; C operation one year, two years to replace.

5) According to A, add every two years. B every year to add; C to add every six months. Every bearing lubrication part mainly for the host.

6) According to A check every year, three years to replace; B check every six months, two years to replace; C check every three months, one year replacement.

( 7) Belt adjustment first run of 500 hours, according to A one year adjustment, after three years to replace; B adjust every six months, two years to replace; C every 3 month, one year replacement. Check whether the pulley is in good condition at the same time.

8) According to A check once every two years; B check once every year; C check once every six months. The fault is replaced.

9) According to A, inspected once every two months. B check once every month; C check once every half month. The fault is replaced.

10) According to A check every year, three years to replace; B check every six months, two years to replace; C check every three months, one year replacement. Loosen the lid after check the spring tension and saddle, damage or change.

11) Exhaust fan to check every day, damage or change.

12) After cooler, in accordance with A check once every two years; B check once every year; C check once every six months. Such as dirty plugging, timely cleaning.

13) According to A check once every two years, six years to replace; B check once every year, three years to replace; C check once every six months, two years to replace. Mainly check the motor insulation and bearing state.

14) According to A check once every three years, six years to replace; B check once every two years, three years to replace; C check once each year, two years to replace.

the article source: GeLinKeEr air compressor

GET IN TOUCH WITH Us
recommended articles
knowledge Info Center FAQ
no data

Greeknhi is committed to the research and development,design, production,sales,installation, repair,maintenance and technical engineering consulting services of efficient and energy-saving air compression system and compressed air purification equipment.The main products of the company are screw air compressor,air dryer,air receiver tank,etc...

Contact us
Contact Person: Evelyn Li
Mob./WhatsApp: +8618850336952
E-mail: evelynli@greeknhi.com
Address: No. 1021 West Yifeng Road,Quangang District,Quanzhou,China.
中国官网:www.greeknhi.com.cn 
Customer service
detect